Project Description

HPLC PT-LC3100

  1. High Pressure Constant Flow Pump for Isocratic and Binary gradient 
  • Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
  • Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
  • Flow precision: RSD≤0.075% (1.00ml/min, H2O,R.T.,8.5MPa)
  • Maximum pressure: 45 MPa
  • Pressure accuracy: ≤±3.0%
  • Pressure pulsation: ≤0.1 MPa

Low-Pressure Gradient Unit for Quaternary

  • Integrated vacuum degasser, 4 channel
  • Composition rang: 0-100%
  • Composition precision: ≤0.2% RSD
  • Composition accuracy: ≤±2.0% 
  1. UV detector
  • Wavelength range: 190-700 nm
  • Wavelength repeatability: ≤0.1 nm
  • Wavelength accuracy: ≤±1.0 nm
  • Bandwidth: 8nm
  • Response time: 0.0 s-5 s
  • Baseline noise: ≤±0.5×10-5 AU
  • Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm(analytical cell)
  • Light source: Deuterium Lamp 
  1. Refractive Index Detector
  • Flow cell type:2 chamber-type
  • Measuring method:Deflection type
  • Refractive Index range:00 to 1.75
  • Measuring range:25 to 512μRIU
  • Drift:2μRIU/h (Pure water 1mL/min, PURGE OFF)
  • Linearity range:≥600μRIU
  • Noise:≤2.5nRIU (Pure water, response : 1.5sec)
  • Response:1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
  • Cell volume:8μL
  • Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)
  1. Evaporative Light Scattering Detector
  • Light source: high intensity halogen lamp
  • Detector: high sensitivity photomultiplier
  • Analogue signal output: 0-1V
  • Heating time:<10min heat-up to 150℃
  • Temperature range: evaporation chamber max 150℃, increase by 1℃, nebulizer max 70℃
  • Gas flow rate: 1-2L/min, recommended pressure 1-2bars
  • Noise<1m Volt(1ml/min)
  • Nebulizer type: venture tube 
  1. Diode Array Detector
  • 512 diodes
  • Wavelength range: 190-760 nm
  • Wavelength repeatability: ±0.1 nm
  • Wavelength accuracy: ±1nm
  • Baseline noise: ≤±1.0×10-5 AU (empty cell, 254 nm, 1.0 s)
  • Drift: ≤2.0×10-4 AU/h (empty cell, 254 nm, 60 min)
  • Path length: 10 mm (analytical cell)
  • Light source: Deuterium Lamp and Tungsten Lamp 
  1. Fluorescence Detector
  • Light source: Xenon flash lamp
  • Wavelength Range: 0, 200 nm to 650 nm (Dual wavelength simultaneous monitoring possible)
  • Spectral Bandwidth: 20 nm
  • Wavelength Accuracy: ±2 nm
  • Wavelength Reproducibility: ±0.2 nm
  • S/N: Water Raman peak S/N 1200 min
  • Cell (capacity, pressure resistance, material): 12 µL; 2 MPa (approx. 20 kgf/cm2); SUS316L, PTFE (fluororesin), quartz
  1. Autosampler
  • Inject volumn range: 0-100 μL (standard)
  • Precision: RSD <0.3%
  • linearity: >0.999
  • Sample residual: <0.01%
  • Number of sample plates: Two of 60 position 2-mL vial plates
  • Syringe: 500 μL
  1. Column oven
  • Column capacity: Three columns, up to 10mm internal diameter, up to
  • 250mm length with guard column
  • Temperature range: room temperature+5.0 to 80℃, settable in 0.1℃ increments
  • Temperature accuracy: ≤±0.5℃
  • Temperature stability: ≤±0.1℃ 

Optional column oven(cooling function)

  • Column capacity: 3 columns up to 300mm length
  • Cooling function temperature range: 5 to 80℃
  • Normal temperature range: room temperature to 100℃
  • Accuracy: 0.1℃
  • Displayer: 4-digit LED
  1. Workstation
  • Internal and external standard calculation methods
  • Automatically displays, prints, exports and starts other programs after the completion of a measurement.
  • Comply with the requirements of the 21 CFR Part 11 directive of the FDA 
  1. On-line degasser
  • Maximum number of degassing Channel: 4
  • Flow path ID: 1.143mm
  • Internal volume: 480μL
  • Wetted Materials: PEEK, Teflon® AF